Mobilizing to address a blocked sanitary sewer requiring bypass pumping
Drilling fluid “frac out” next to river bed. Pumping system delivered and setup same day, fluid pumped backed to drill mud reclaimer 3000’ away
Emergency Response
Sink hole and watermain collapse
Emergency Sewage Bypass Pumping
- Emergency trunk failure, set-up immediately and operational for 3+ months
Stormwater Bypass Pumping
12” critically silenced pump capable of 5.7 million gallons per day, with filtered discharge to environmentally sensitive wetlands.
Sewage Bypass Pumping
Sanitary bypass pumping using two 12” pumps on primary and one 12” pump on backup. Pumping 10 million gallons per day.
Stormwater Management Pond (SWMP) drainage to allow for removal of sediment from base of pond
Storm water bypass with discharge treatment and filtration system (up to 2.88 million gallons/day)
Vacuum wellpoint system pumps in excess of 540,000 gallons /day of groundwater to maintain dry excavation
- Creek dewatering with fish baskets
Dewatering system designed for complex layer geology using vacuum wells at varying depths and stages
Diesel Hudig vacuum wellpoint pump keeping excavation dewatered in Dubai
Industry seminar on proper dewatering system and wellpoint installation
Mine dewatering 1.4 million/gallons day at 300’ vertical lift
New type of dewatering wellpoints used to dewater trench with all discharge being re-injected back into aquifer
Stormwater management pond dewatering using vacuum wellpoint system and discharge filtration using weir tanks (Enviro-Tank)
Sanitary trunk sewer is blocked requiring emergency bypass pumping (up to 19.4 million gallons/day).
Hurricane Ike response. Waste water treatment plant experienced flow increase of 33% over permanent pump capacity. System mobilized and setup on Sunday afternoon during storm within 4 hours of call
Vacuum educator wells lowered ground water levels in silty ground for new sewer installation construction
Extreme suction lift for storm pond dewatering
Vacuum wellpoint system installed in a 2 meter subcut using Hudig wellpoint pump with oil-less vacuum (fuel consumption of less than 3 litres/hour)
Dewatering wellpoint system installed in a subcut
Sewage Bypass Pumping - Three 12” Godwin Critically Silenced diesel bypass pumps performing a 10 million gallons/day sanitary bypass
Creek Bypass Pumping - Automated pumps set up on creek bypass pumping station
Mine dewatering- Aquatech uses Godwin pumps powered with CAT engines for the ultimate in reliability and support
Storm water management pond dewatered using a 6” Godwin Silenced Dri-Prime diesel pump in a residential area
Discharge flows up to 2.88 million gallons/day with turbidity levels filtered from as high as 1000 NTU to levels as low as 2 NTU
Storm water management pond rehabilitation- under construction
Aquatech technicians supporting pumping operation with heat tracing on discharge pipe for a northern mine dewatering project.